language

HUATAO GROUP
News & Events

We Help Customers To Meet The Great Challenges Of Our Time.

VIEW PRODUCTS
scroll down

Back to Overview

Self-Cleaning Overband Magnet on a Shuttle Conveyor: Does Reversible Belt Direction Matter?

Nov 28,2026

Author:

HUATAO

Self-Cleaning Overband Magnet on a Shuttle Conveyor: Does Reversible Belt Direction Matter?

 

Key Takeaways

  • A shuttle conveyor reverses flow to fill alternate stockpiles, so the magnet sees material from two directions instead of one.
  • Asymmetric pole designs can lose 30–45% capture when the belt runs backward.
  • The working gap changes between directions because the tight/slack side alternates.
  • Fixed-side iron discharge can move tramp metal into the "clean" stockpile unless the chute geometry controls it.
  • Seeded capture tests must be repeated in both travel directions before sign-off.

Summary Table

Item

Description

Function

Continuous removal of tramp iron from a bidirectional (reversing) shuttle conveyor

Typical equipment

Suspended self-cleaning overband separator or permanent overband unit

Critical variables

Pole symmetry, working gap (both directions), bed depth, exposure time, discharge geometry

Capture window

t = L/v — effective magnetic length divided by belt speed

Direction penalty (asymmetric design)

30–45% capture loss in the reverse pass

Fix

Symmetric poles, centered installation, two-direction gap survey, chute with rejection flap

Maintenance focus

Cleaning-belt tracking and tension, gap log, seeded tests, doubled flex-cycle wear

Case Study

Customer type: Multi-product aggregates terminal operating a four-bay stockyard.

Ore type: Crushed granite and road-base blends, 150–300 mm lump, damp after rain.

Operating conditions: 1,400 mm shuttle conveyor, 2.0 m/s both directions, 1,100 t/h, tripper dwell filling one bay at a time.

Problem: Iron recovery audits found the reverse pass capturing only ~55% of seeded pieces versus ~93% forward; two bucket teeth and several plate fragments reached the tertiary cone over one season, and steel fragments were reported in the "clean" sand pile after reverse-running weeks.

Solution: The existing asymmetric-pole suspended unit was replaced with a symmetric-pole self-cleaning overband installed at the span midpoint; the working gap was reset from a two-direction sag survey (worst case 330 mm); a baffled discharge chute with an intermediate rejection box was fitted between the pile edges; and acceptance was defined as seeded capture agreement within 10% across both directions.

Result: Seeded capture settled at 91–96% in both directions; iron reaching any product pile dropped to zero over the following six months; crusher liner incidents fell from three per year to zero; weekly rejection-box audits became the plant's leading indicator for burden-path drift. The plant's engineers now run the same two-direction protocol on every suspended iron magnet they buy.

FAQ

Q1: Does belt direction really matter for an overband magnet?

A: Yes. Direction swaps the magnet's leading and trailing edges, changes the working gap through tight/slack side alternation, and changes where released iron travels. A symmetric, centered installation removes the penalty; an asymmetric one can lose 30–45% capture in reverse.

Q2: Where should the magnet sit on a shuttle conveyor?

A: At the midpoint of the carrying strand, so both travel directions present the burden symmetrically. Near-pulley positions inherit transfer-point turbulence and make one direction geometrically weak.

Q3: How do I set the working gap on a reversing belt?

A: With the belt loaded, measure clearance at the magnet station in both directions and set for the worst case. Expect a 20–40 mm difference between directions on typical stockyard spans, and log the gap monthly.

Q4: Permanent or electromagnetic for a shuttle conveyor?

A: Permanent units suit stable gaps and low power budgets; electromagnetic overbands deliver deeper flux for heavy or variable burdens and allow remote de-energizing. Match the choice to measured burden depth, not price alone.

Q5: Why is iron ending up in my clean stockpile?

A: Almost always re-entrainment: pieces release at the magnet's far edge, miss the fixed chute, and ride the belt to whichever pile is active. Fix the trajectory with a baffle and add a rejection box between the pile edges.

Contact Us

Contact: Annie Lu

Email: annie.lu@huataogroup.com

Phone / WhatsApp: +86 180 3242 2676

Website: http://www.tufflexscreen.com

We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.

Contact Us

E-mail:
team3@huataogroup.com 

Phone/WhatsApp:
+86-13331385676

Address:
NO.298 Zhonghua North Street,Shijiazhuang city, China.