Consistency Transmitter
+
  • Consistency Transmitter

Consistency Transmitter

The consistency transmitter has high sensitivity, good anti-vibration performance, and is almost insensitive to the slurry flow rate. It can be applied to all aspects of pulp concentration detection and control in papermaking and pulping processes of papermaking enterprises.
File Download:
Click here!
  • Product Details
  • Description

    The consistency transmitter has high sensitivity, good anti-vibration performance, and is almost insensitive to the slurry flow rate.
    It can be applied to all aspects of pulp concentration detection and control in papermaking and pulping processes of papermaking enterprises.

     

    Specification

    Working Range 1~16% concentration (according to measuring components)
    Sensitivity Better than ±0.005%
    Measurement Accuracy Close to sensitivity under stable conditions
    Damping Time 1~100S
    Max Working Pressure 1MPa, 80°C
    Shell Material Cast aluminum
    Contact Medium Part Stainless steel
    Motor 3-phase 380VAC, 370W, IP54
    Analog Signal Output 4~20mA, load 0~750Ω

     

    Features

    ● Liquid crystal display, which can realize multi-point, parabolic calibration and easy to operate calibration;
    ● Signal damping and filtering are very low,signal to noise ratio is high, and has high precision;
    ● Not affected by pulp, fiber type, freeness, Kappa number, flow rate, pressure, etc.;
    ● It is little affected by pH and temperature, and the temperature can be compensated;
    ● Unaffected by pressure, air bubbles and electrical conductivity;
    ● Fast response, short reaction time and control dead time, and good controllability;
    ● It can be installed on horizontal, vertical or inclined pipes. The sensor shaft should be horizontal and the motor should be under the sensor.

     

    Application

    It can be applied to all aspects of pulp concentration detection and control in papermaking and pulping processes of papermaking enterprises. 

    ◆ Ambient temperature 0~60 0C
    ◆Medium temperature 0~90 0C
    ◆Environmental humidity ≤85%RH
    ◆External magnetic field ≤400A/m (5 Oersted)
    ◆Dilution water pressure 0.2~0.4MPa
    ◆Vibration amplitude ≤0.05mm frequency ≤25Hz
    ◆Slurry flow rate 0.5~5m/s